8 This difficulty is overcome in modern high flow-rate evaporators; in which there is a low hold up volume and in which little or no mixing occurs. Examples are long-tube evaporators with climbing or falling films, plate evaporators, centrifugal evaporators, and the various scraped-plate thin-film evaporators.
|
Steam is used in the jacket of the evaporator at a pressure of 170 kPa (abs). If the overall heat-transfer coefficient is 6000 J m-2 s-1 °C-1, estimate the quantity of tomato juice feed per hour. Take heating surface as 3 m long x 0.04 m diameter. Mass balance: basis 100-kg feed
Heat balance Condensing steam
temperature at 170 kPa (abs) = 115°C from Steam
Tables.